............................................................................................................................................... >> Weighing Indicator

HB-8260

HB-SDJB4/8

HB-8211
 HB-8212
HB-8212X1
HB-8215/HB-8216(A/B)
HB-8218
HB-8220

>> HB-8212x1 ........................................ BATCHING CONTROLLER

Store up to 100 items setpoint by individual code no. Multi-function, batching control for dynamic weighing systems and process weighing control applications.

Flexible Operation - Versatile Control Programs are Built in Software Module

The-HB-8212 x 1 is designed for flexible operation. They may be used for normal batching or loss in weighing batching. Both may be operated in either the fully automatic mode or user programmed mode.
Fully automatic mode allows the batching operation to be started and completed automatically without the intervention or assistance of an operator.

User programmed mode allows the operator to have some control of the batching process, such as manually adding ingredients during the operation, or manually starting a new batch.
In either case, the programmability of the HB-8212x1 allows the operator to enter settings that adjust the unit for almost any environmental factor. Additionally, auto zero maintenance automatic free fall compensation, and the comparator inhibitor function.

>> Setpoint Memories
Up to 100 coded sets of setpoint values can be stored into memory, and easily recalled from the front panel, personal computer (via, serial interface), or PLC.
The 100 coded memory information blocks (00 to 99).
Contain:
  • Final Weight
  • Free Fall
  • Preliminary
  • Over and Under Weighing
Technical Specifications:
MODEL NO HB-8212x1
INPUT
AND A/D
CONVERSION
Input sensitivity 0.6 V/D~120 V/D
Zero adj. Range 0mV to 30 mV
Loadcell excitation 12VDC, 280mA (Voltage sensing)
Input impedance 10M(Min)
A/D conversion method
A/D resolution 1,000,000 Counts
A/D conversion rate 100 times per second
DIGITAL
SECTION
Weight display 13mm, 7digits high intensity cobalt-blue fluorescent tube
Under zero Indication Negative "-" sign
Over Load Indication Input signal > 36mV "------"
Annunciators Center of ZERO, POWER, TARE, GROSS, NET, COUNT, STABLE, FUNC. * In Function Setting
Switches 0-9 Numeral key, ZERO, TARE, GROSS/NET, PRINT, WT/CN, FUNC. * In Function Setting
Digital set-up parameters Motion detection... 1.0D/1 sec., 2.0D/1 sec., 3.0D/1sec., 1D/0.5sec
2D/0.5sec., 3D/0.5sec, 4D/0.5sec., 6D/0.5sec
9D/0.5sec.
Zero track... No zero tracking, 0.5D/2sec., 0.5D/1sec., 1.0D/2sec
1.0D/1sec., 1.5D/2sec., 1.5D/1sec.,2.0D/2sec.,
2.0D/1sec., 3.0D/2sec.
Decimal point... None or 1,2,3 or 4 decimal places
Count by ... 1,2,5,10,20,50
Max. capacities... 10,000 counts x min. increment
Digital filter... None or 2,4,6,8,16,32 time of average
Zero range... 2%, 5%, 25%, 100% of F.S
Conversion rate... 1/sec., 5/sec., 10/sec., 20/sec. ...etc
Unit... kg, t, g, lb, oz
Calibration (F.D.A.C) zero & span full digital calibration
Non-linearity 0.01% of full scale
GENERAL Temp. coefficient zero... 0.2 V RTI
span... 15ppm/C of reading
Real panel load cell input... 7 pin industrial circular connector
ext. control... 9 pin D-type connector (Zero, Tare, Gross/ Net, Print, WT/CN, Sensor Input)
Power source (factory preset) 110, 220VAC 10% ,50/60HZ
Net weight 2.5KG
Operating Temperature -10C to + 40C (+14F to + 104F)
Operating Humidity Max. 90% RH (Non-condensing)
Physical dimensions 202 (W) x 105(H) x 152(D) m/m without load cell connector
202 (W) x 105(H) x 220(D) m/m with load cell connector

>> Physical Dimensions Outline


HB-8260

HB-SDJB4/8

HB-8211
 HB-8212
HB-8212X1
HB-8215/HB-8216(A/B)
HB-8218
HB-8220

...................................................................................................................................>> Back


HOLBRIGHT WEIGHING SYSTEMS CD., LTD.
4F, No. 31, Lane 21 Min Chuan East Rd. Sec. 6 Nei Hu. Taipei. Taiwan R.O.C.
TEL: 886-2-8792-0786 FAX: 886-2-8791-2380
E-MAIL: hobright@ms11.hinet.net
     holbright@xuite.net
http://www.holbright.com.tw